GC9310 GAS CHROMATOGRAPH
-
Min Order
1
-
Product Unit
Pieces
-
Price
$ 5.47 - 13.99
-
Origin
China Mainland
-
Payment
- Contact Now Start Order
- Favorites Share
- Description
Product Detail
INTRODUCTION:
Display: LCD
Interface: RS232 serial interface and USB interface
Power Supply: 110/220 VAC, 50-60±1Hz
Detector: FID, ECD, TCD, NPD, FPD
Column: packed column, capillary column
Workstation Version: English
Dimensions: 800 × 650 × 570 mm
N.W.: 65Kg
Packing Dimensions: 800×650×570mm
G.W.: 80Kg
Packing: Wooden Box
MAJOR APPLICATION FIELDS:
Building Indoor Environment Testing (Benzene, toluene, xylene, TVOC, NMTHC)
Natgas, Artificial Gas, Coal-Mine Gas, LPG, Mixed Gas, High Purity Gas (Ar, He, O 2 , N 2 , CO 2 )
Food Additives & Pesticide Residue (organophosphorus, organochlorine, amino acid methyl ester )
Alcohol & Liquor (methanol, ethanol, ethyl acetate, ethyl butyrate, acetaldehyde)
Dissolved Gas (hydrogen, methane, ethane, ethylene, acetylene, carbon monoxide, carbon dioxide)
Petrochemical Testing and Fine Chemicals (crude oil, gasoline, essence)
FEATURES:
? GC9310 gas chromatograph control circuit using micro-processing systems and man-machine conversation menu with real-time display of all
parameters, setting values and actual values.
? GC9310 gas chromatograph can be installed packed column and capillary column, with column automatic cooling, automatic rear door
opening and pressure displaying functions.
? GC9310 gas chromatograph using a double stable pneumatic system, single packed column structure and a separate set of capillary shunt
valve, it can be installed capillary flow, and could be installed hydrogen and air flow in different carrier gas, these separate ways can be adjusted
independently.
? GC9310 gas chromatograph column with microcomputer temperature control system and excellent anti-interference, anti-temperature
overshoot ability, column, sampler, TCD and capillary injector can be used for wide temperature range and high precision temperature control,
the column oven temperature can be programmable to five-stage heat up. It can also microcomputerized the FID amplifier range and polarity
selection, TCD current settings and display.
? GC9310 gas chromatograph also has a temperature limit setting, analysis time count, temperature kepting, dynamic scan the actual
temperature, opens the rear door automatically when cooling the column box, power data protection.
MAJOR SPECIFICATIONS AND FUNCTION:
Column Box Temperature Control | Temperature Range | RT 5°C~399°C(Incremental 1°C) |
Temperature Accuracy | Better than±0.1°C(200°C) | |
Temperature-programmed magnification | 10 | |
Temperature-programmed rate setting | 0.1°C~40°C/min(Incremental 1°C)(1°C -200°C) 25°C/min(Incremental 1°C)(above 200°C) | |
Magnification temperature time | 0~655min(Incremental 1min) | |
Temperature object | column box, detectors, samplers | |
TCD | Sensitivity | =3000mv.ml/mg |
Baseline noise | =20µv | |
Baseline draft | =50µv/30min | |
Gas flow rate stability | =1% | |
High sensitivity TCD | =6000mv.ml/mg | |
FID | Detection limit | =8×10 -12 g/s |
Baseline noise | =5×10 -14 A | |
Baseline draft | =2×10 -13 A/30min | |
Temperature (sampler,FID,TCD) | Stabilization time | 30min |
Temperature Range | RT 5°C~399°C(Incremental 1°C) | |
Temperature Accuracy | Better than ±0.1°C(200°C) |