Huawei OptiX Metro 100 SDH PDH Equipment
-
Min Order
1
-
Product Unit
Pieces
-
Origin
China Mainland
-
Payment
- Contact Now Start Order
- Favorites Share
- Description
Product Detail
Quick Details
Place of Origin: | Guangdong, China (Mainland) |
Brand Name: | Huawei |
Model Number: | Metro 100 |
Type: | SDH PDH Equipment |
Switch Capacity: | 1.25Gbit/s full higher order and lower order cross connect capacity |
Fuse Capacity: | 1A |
Dimension: | 442 mm (W) x 220 mm (D) x 43.6mm |
Weight: | 2.9kg |
Power supply: | DC: -48V DC or -60V DC AC: 220V |
Service model: | 4xE1+2xFE+2xSTM-1: Support |
Networking Mode: | Supports multiple SDH networking |
Auxiliary Interface: | 10M/100M NM interface, external UPM management port |
Basic function: | Transmits and receives 4xE1 services |
Packaging & Delivery
Packaging Details: | Original carton package |
Delivery Detail: | Within 5 working days after the receipt of the payment |
Huawei OPTIX Metro 100 SDH PDH Equipment
Product Description
The OptiX Metro 100 is a type of STM-1 case-shaped equipment developed by Huawei Technologies Co., Ltd. (hereafter referred to as Huawei). The OptiX Metro 100 is mainly used at the access layer of transmission networks, with the features of high integration, flexible installation modes, and low power consumption.
The OptiX Metro 100 is used at the access layer of a transmission network. The OptiX Metro 100 provides STM-1 optical interfaces and works with the other access-layer equipment to form an entire equipment group at the access layer of a transmission network, therefore constructing a complete OptiX product series of Huawei.
Appearance
The OptiX Metro 100 is new-generation optical transmission equipment developed by Huawei for the access layer.
The OptiX Metro 100 is a type of case-shaped equipment. The dimensions of the chassis are: 442 mm (W) x 220 mm (D) x 43.6 mm (H). Except for the power supply module, all the functional units are integrated into the one board.
The OptiX Metro 100 supports a service model of 4xE1+2xFE+2xSTM-1.
Front view of the OptiX Metro 100
Rear view of the OptiX Metro 100
Specifications
Functions and features of the PDH unit
Functions and Features | Description |
---|---|
Basic function | Transmits and receives 4xE1 services. |
Alarm and performance event | Supports various alarms and performance events, which facilitates the management and maintenance of the equipment; supports the alarm reversion function. |
Clock source | ? Supports the settings and query of 4xE1 clock re-timing function. ? Supports the extraction of E1 clocks over channel 1 only. |
Maintenance features | ? Supports inloop and outloop at E1 ports so that faults can be located quickly. ? Supports the setting of overhead bytes to be sent/received, thus enabling the board to function as an overhead instrument. ? Supports the settings of thresholds for the excessive errors. ? Supports pseudo-random binary sequence (PRBS). |
Overhead processing | ? Processes path overheads at the VC-12 rate. ? Supports the settings and query of overhead bytes such as J2 and V5. |
Other functions | Supports three types of E1 interfaces: RJ-45 (120 ohms), BNC (75 ohms), and DB15 (X.21). |
Functions and features of the SDH unit
Functions and Features | Description |
---|---|
Basic function | Transmits and receives 2xSTM-1 optical signals. |
Alarm and performance event | Supports various alarms and performance events, which facilitates the management and maintenance of the equipment; supports the alarm reversion function. |
Clock source | Supports the line clock extraction function. |
Maintenance features | ? Supports the outloop on SDH optical interfaces and inloop and outloop on VC-4 paths, and the automatic release of loopbacks. ? Supports the setting of overhead bytes to be sent/received, thus enabling the board to function as an overhead instrument. ? Supports the settings of thresholds for the excessive errors. ? Supports PRBS. |
Overhead processing | ? Provides transparent DCCs and orderwire byte channels. ? Supports the setting and query of J0, J1, and C2 bytes. |
Optical module | ? Supports the query of the manufacturing information about SFP modules. ? Supports single-fiber bidirectional SFP optical modules. ? Supports the status query of SFP modules. ? Supports hot-swapping of SFP optical modules. ? Supports the setting and query of lasers. ? Supports the automatic laser shutdown (ALS) function of lasers. |
Applications
Application of the OptiX Metro 100 on transmission networks
Features
The OptiX Metro 100 supports various services interfaces, power input modes, and installation modes, and a high security mechanism.
Various E1 Service Interfaces
The OptiX Metro 100 supports three types of physical interfaces:
? RJ-45 (120 ohms)
? BNC (75 ohms)
? DB15 (X.21)
High Network Security Mechanism
The OptiX Metro 100 supports the Radius security control, that is, the user names and passwords of all NEs are managed in a unified manner through the server of the user. Any user must pass the authentication before logging in to the NE. Therefore, the network security is high.
Support for Device Stack
The OptiX Metro 100 supports a maximum of 1+3 device stack (one master device and three slave devices), that is, 16xE1 services are configured into one optical channel.
Support for Default Settings
The OptiX Metro 100 is configured and maintained with the NMS and Web LCT, supporting the "one-click recovery to default settings" function.
Various Installation Modes
The OptiX Metro 100 can be installed in various ways. Therefore, you can select a proper installation mode according to the actual situation.
The OptiX Metro 100 supports the following installation modes:
? Cabinet-mounting (19-inch cabinet, ETSI 600 mm cabinet, or ETSI 300 mm open cabinet)
? Wall-mounting
? Desk-mounting
NOTE:
When the OptiX Metro 100 is installed in a cabinet, leave a space of 1U above and below the chassis to facilitate heat dissipation and to prevent high temperature air from other equipment.
Various Power Input Modes
The OptiX Metro 100 supports the following power input modes:
? 100 V to 240 V AC power input
? -48 V to -60 V DC power input
The OptiX Metro 100 supports one AC power input and one DC power input at the same time. The two power inputs back up for each other. The AC power input is controlled by a switch, whereas the DC power input is not. When the AC power input and the DC power input are unavailable at the same time, the OptiX Metro 100 reports the VOLT_LOS alarm indicating a power failure.
Low Power Consumption, Natural Heat Dissipation, and High Integration
? Supports a maximum power consumption of 16 W only.
? Supports natural heat dissipation and produces low noise.
? Supports high integration.
All the features can help carriers minimize their OPEX.
Packaging & Shipping
1.Trade terms: FOB,CIF,CFR,etc
2.Price Terms: L/C,D/P,T/T,Western Union,PAYPAL
3.Payment Terms: T/T in advance
4.MOQ: 1 pcs
5.FOB Price:US $1 - 1,000 / Piece
6.Port: Shanghai
7.Lead time: Within 5 working days after receipt payment.
8.Shipment: Express, Air, Sea
9.Supply capability: 200 Piece/Pieces per Week
10.Sample availability: Yes( not free)
11.Package information: carton package with Huawei original package
Chucheng Information is one of the leading China huawei optix metro 100 sdh pdh equipment manufacturers, which is also one of the famous brands. We employed well-educated and experienced workers and introduced world's leading equipment. Now, with large quantity of products in stock, we warmly welcome you to buy our discount and cheap equipment at low price with us.
- DPZ-218 Channels Power Distribution Box 1 Pieces / (Min. Order)
- DPZ-210 Channels Power Distribution Box 1 Pieces / (Min. Order)
- PYGL440 Distribution Page Linkage Line 1 Pieces / (Min. Order)
- More Position Tube End 1 Pieces / (Min. Order)
- Grinder Dust Collector Equipment 1 Pieces / (Min. Order)
- PL Single Dust Purification Equipment 1 Pieces / (Min. Order)
- Distribution Box 1 Pieces / (Min. Order)
- Irrigation Sprinkler Water Distribution Testing System 1 Pieces / (Min. Order)
- 2 Pair STB Distribution Box With Module Indoor Types HY-30203 1 Pieces / (Min. Order)
- 10kv or 35kv Distribution Transformer 1 Pieces / (Min. Order)
- Lower Price Bosch EPS 619 Diesel Fuel Injection Pump Test Bench 1 Pieces / (Min. Order)
- Clear Exhibition Tent 1 Pieces / (Min. Order)
- WXD100S Microwave Drying Sterilization Equipment 1 Pieces / (Min. Order)
- Outdoor Power Distribution Cabinet 1 Pieces / (Min. Order)
- 100% Polyester 180gsm Moisture Wicking Sublimation Short Sleeve Polo Shirt 1 Pieces / (Min. Order)
- Microwave Rubber Vulcanization Equipment 1 Pieces / (Min. Order)
- Microwave Extraction, Drying And Sterilization Equipment 1 Pieces / (Min. Order)
- 17-19 Way Iron Electrical Distribution Box with Automatical Open and Locking Button 1 Pieces / (Min. Order)
- KYN61-40.5KV 35KV Armoured Movable AC Power Distribution Switchgear Factory Price 1 Pieces / (Min. Order)