Residential Water Source Heat Pumps For Cooling And Heating
-
Min Order
1
-
Product Unit
Pieces
-
Origin
China Mainland
-
Payment
- Contact Now Start Order
- Favorites Share
- Description
Product Detail
Residential water source heat pumps for cooling and heating
This is residential water source heat pumps which can supply both cooling and heating functions. Use high quality one-way valve and solenoid valve for reliable cooling and heating, professional control system.
With unique design and long time testing, we can ensure the best performance.
With the high standard and professional workers, we ensure the high quality.
Product Info.
Compressor | Copeland scroll or Panasonic scroll |
Capacity | 11KW, 17KW, 24KW |
Refrigerant | R410A |
Condenser | “ND” Shell & Coil heat exchanger |
Evaporator | Shell & tube, tube in tube or plate type heat exchanger |
AC contactor & Relay | Schneider |
Electronic expansion valve | Japan Saginomiya or World No.1 Sanhua |
Reversing valve | World No.1 Sanhua |
Controller | LCD |
Package | Wooden case or Carton |
Fasteners | Stainless steel 304 |
Additional Info.
Delivery time | 25 days after order confirmed |
Warranty time | 24 months after shipment |
Payment term | T/T or L/C at sight |
Production capacity | 300 units per month |
Brand | MES or OEM |
Parameters
Cooler-RW series(Residential Water source cooling & heating heat pump | CL-RW-1609 | ||||||
CL11s-RW5 | CL17s-RW5 | CL11-RW5 | CL17-RW5 | CL24-RW5 | |||
Underground water open loop | Rated cooling capacity | KW | 11 | 17 | 11 | 17 | 24 |
Rated input power for cooling | KW | 2.15 | 3.34 | 2.11 | 3.2 | 4.72 | |
Rated input current for cooling | A | 9.55 | 14.84 | 3.98 | 6.04 | 8.91 | |
Cooling performance coefficient (EER) | / | 5.12 | 5.09 | 5.22 | 5.32 | 5.09 | |
Rated heating capacity | KW | 9.5 | 16 | 9.5 | 16 | 22 | |
Rated input power for heating | KW | 2.59 | 4.38 | 2.59 | 4.31 | 6.09 | |
Rated input current for heating | A | 12.33 | 20.87 | 4.89 | 8.15 | 11.52 | |
Heating performance coefficient (COP) | / | 3.67 | 3.65 | 3.67 | 3.71 | 3.61 | |
Application side heat exchanger water flow | M3/h | 1.89 | 2.92 | 1.89 | 2.92 | 4.13 | |
Heat source side heat exchanger water flow | M3/h | 1.03 | 1.59 | 1.03 | 1.59 | 2.25 | |
Ground source closed loop | Rated cooling capacity | KW | 10 | 16 | 10 | 16 | 22 |
Rated input power for cooling | KW | 1.96 | 3.17 | 1.95 | 3.13 | 4.38 | |
Rated input current for cooling | A | 8.7 | 14.11 | 3.68 | 5.91 | 8.28 | |
Cooling performance coefficient (EER) | / | 5.11 | 5.04 | 5.13 | 5.12 | 5.02 | |
Rated heating capacity | KW | 8 | 12 | 8 | 12 | 16 | |
Rated input power for heating | KW | 3.07 | 4.43 | 3.04 | 4.58 | 5.99 | |
Rated input current for heating | A | 13.27 | 19.17 | 5.66 | 8.52 | 11.15 | |
Heating performance coefficient (COP) | / | 2.61 | 2.71 | 2.63 | 2.62 | 2.67 | |
Application side heat exchanger water flow | M3/h | 1.38 | 2.06 | 1.38 | 2.06 | 2.75 | |
Heat source side heat exchanger water flow | M3/h | 1.72 | 2.58 | 1.72 | 2.58 | 3.44 | |
Power supply | 1N 220V/50Hz (Special power supply for option) | 3N 380V/50Hz (Special power supply for option) | |||||
Compressor | Type | Hermetic scroll type | |||||
Quantity | PCS | 1 | 1 | 1 | 1 | 1 | |
Heat source side heat exchanger | Type | Shell & coil heat exchanger | |||||
Connection size | DN | DN20 | DN25 | DN25 | DN25 | DN25 | |
Application side heat exchanger | Type | Shell & coil heat exchanger | |||||
Connection size | DN | DN20 | DN25 | DN25 | DN25 | DN25 | |
Protections | 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc. | ||||||
Refrigerant | Type | R410A | |||||
Quantity | KG | 2.6 | 3.3 | 2.6 | 3.3 | 4.2 | |
Dimension | mm | 790x415x590 | |||||
Wooden case package dimensions(L*W*H) | mm | 836x461x752 | |||||
Net weight | KG | 68 | 95 | 65 | 95 | 135 | |
Gross weight | KG | 78 | 105 | 75 | 105 | 145 | |
Noise | DB(A) | =53 | =55 | =55 | =55 | =58 | |
Note: | |||||||
1. Underground water open loop type cooling standard condition: use side water input/output temperature 12?/7?; source side water input/output temperature 18/29?. | |||||||
Underground water open loop type heating standard condition: use side water input/output temperature 40?/45?; source side water input/output temperature 15?/-a. | |||||||
2. Ground source closed loop type cooling standard condition: use side water input/output temperature 12?/7?; source side water input/output temperature 25?/30? Ground source closed loop type heating standard condition: use side water input/output temperature 40?/45? ; source side water input/output temperature 5?/-a. | |||||||
3. "-a " means the water flow under cooling standard condition. | |||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret. |
MES, one of the professional manufacturers and suppliers of residential water source heat pumps for cooling and heating in China, has been developing and manufacturing heat pumps for over 10 years and become one of the famous such brands. In order to make customers 100% satisfied, we also offer installation service. Now, don't hesitate to buy high quality residential water source heat pumps for cooling and heating made in China at competitive price with our factory.
- High Voltage Power Fuse Type W For Motor Protection 1 Pieces / (Min. Order)
- Mechanical Vibration Type Dust Collector 1 Pieces / (Min. Order)
- Mechanical S5070 Type Flat Machine 1 Pieces / (Min. Order)
- Mechanical Tensile Pressure Automatic Film Wrapping Machine 1 Pieces / (Min. Order)
- Mechanical Three Roller Asymmetrical Bending 1 Pieces / (Min. Order)
- Rechargeable Emergency Driver Module 36w Panel Light With 12w Emergency Lighting 1 Pieces / (Min. Order)
- The High Quality Exclusive Bamboo Paper Fan For Japanese Dancing 1 Pieces / (Min. Order)
- Mechanical Diaphragm Metering Pump DPMXAF 1 Pieces / (Min. Order)
- Mechanical Diaphragm Metering Pump DPMWAF 1 Pieces / (Min. Order)
- Mechanical Diaphragm Metering Pump DPMXW 1 Pieces / (Min. Order)
- Mechanical Diaphragm Metering Pump DPMWS 1 Pieces / (Min. Order)
- Three Part Curly 10-20inches Indian Virgin Hair Lace Top Closure 5x5 Baby Hair Fast Shipping 1 Pieces / (Min. Order)
- Peruvian Body Wave Virgin Remy Human Hair Weft 3 Bundles 300gram Black Hair Weaving 1 Pieces / (Min. Order)
- led high bay light 100W led high bay lamp factory warehouse light 1 Pieces / (Min. Order)
- Pneumatic Shaft Parts Processing 1 Pieces / (Min. Order)
- Male Enhancement Chemical Steroid Hormone Raw Powder Methenolone Enanthate 1 Pieces / (Min. Order)
- Hexagon Acorn Nuts With Flange 1 Pieces / (Min. Order)
- 55 Inch android Touch Screen Kiosk,Wifi/3g Advertising Player Digital Signage 1 Pieces / (Min. Order)
- Residential Air Source Heat Pumps For Cooling And Heating 1 Pieces / (Min. Order)